Initial Calibration Verification Standard 3 (500 mL)

SKU: ICV-3

Description

CLP Standards for ICP & ICP-MS Our Contract Laboratory Program (CLP) standards allow you to Calibrate with Confidence®. The standards are to be used in conjunction with the Statement of Work for Inorganic Analysis; Multi-Media/Multi-Concentration Document Number ILM 05.3/ISM 01.2. The final ICP check, performed in our own laboratories, is your stamp of assurance. We calibrate our instruments with traceable reference materials and show you the actual found value of the solution you receive, not just an ideal, calculated number as so many other standards manufacturers do. The combination of elements, concentrations and matrices listed have been diagnosed by SPEX CertiPrep for convenience of use and stability. US EPA SOW ILM 05.3/ISM 01.2 gives specific procedures for the methods of analysis, target elements, and concentrationlevels. Standards are specified not only by the elements present and their relative concentrations, but also the order and frequency of running standards, blanks and samples. Details of these specifications may be found in the US EPA SOW ILM 05.3/ISM 01.2 in the following sections: • Exhibit C, Inorganic Target Analyte List (TAL) • Exhibit D, Analytical Methods • Exhibit E, QA/QC Requirements Initial Calibration Verification for CLP Methods The US EPA retains analytical services through the Contract Laboratory Program (CLP). The CLP follows detailed SOPs derived from EPA methods. The CLP methods require calibration of analytical instrumentation whithin the expected quantitative range (ICAL standards) and additional CLP QA standards (ICV standards) to verify the calibration curve at each of the selected wavelengths that wil be used for sample analysis. Our verification standards contain all of the elements on the TAL list and are independent standards for testing an instruments calibration curve. SPEX CertiPrep's ICV standards are designed to be used with their corresponding instrument calibration standards (ICAL). We recommend dilution of ICV standards to a range within your instruments calibration curve. A dilution of 20-fold is recommended.

Intended Use

Multi-element standards for ICP and ICP-MS instrumentation

More Information

Accredited by A2LA to ISO/IEC 17025/2017 and ISO 17034:2016|Certified to DQS to ISO 9001:2015|Calibrate ICP and ICP-MS instrumentation prior to analysis|Contains all of the elements on the Target Analyte List (TAL) list

Product Information

  • BrandSpex
  • Volume500 mL
  • Unit of MeasureEA
  • Storage Condition15 to 30°C
  • Product TypeInorganic Standard
  • Raw MaterialFive 9s & Purification as available
  • CertificationSingle: Direct ICP Analysis

Notifications

  • warning
    This item has been deemed hazardous Additional shipping fees and permits may apply.

Component Table

Calcium 500 µg/mL 5% HNO3
Magnesium 500 µg/mL 5% HNO3
Potassium 500 µg/mL 5% HNO3
Sodium 500 µg/mL 5% HNO3
Aluminum 200 µg/mL 5% HNO3
Barium 200 µg/mL 5% HNO3
Arsenic 100 µg/mL 5% HNO3
Iron 100 µg/mL 5% HNO3
Lead 100 µg/mL 5% HNO3
Selenium 100 µg/mL 5% HNO3
Thallium 100 µg/mL 5% HNO3
Cadmium 50 µg/mL 5% HNO3
Cobalt 50 µg/mL 5% HNO3
Manganese 50 µg/mL 5% HNO3
Nickel 50 µg/mL 5% HNO3
Vanadium 50 µg/mL 5% HNO3
Zinc 50 µg/mL 5% HNO3
Copper 25 µg/mL 5% HNO3
Silver 25 µg/mL 5% HNO3
Chromium 20 µg/mL 5% HNO3
Beryllium 5 µg/mL 5% HNO3