- Top rated


Description
CLP Standards for ICP & ICP-MS Our Contract Laboratory Program (CLP) standards allow you to Calibrate with Confidence®. The standards are to be used in conjunction with the Statement of Work for Inorganic Analysis; Multi-Media/Multi-Concentration Document Number ILM 05.3/ISM 01.2. The final ICP check, performed in our own laboratories, is your stamp of assurance. We calibrate our instruments with traceable reference materials and show you the actual found value of the solution you receive, not just an ideal, calculated number as so many other standards manufacturers do. The combination of elements, concentrations and matrices listed have been diagnosed by SPEX CertiPrep for convenience of use and stability. US EPA SOW ILM 05.3/ISM 01.2 gives specific procedures for the methods of analysis, target elements, and concentrationlevels. Standards are specified not only by the elements present and their relative concentrations, but also the order and frequency of running standards, blanks and samples. Details of these specifications may be found in the US EPA SOW ILM 05.3/ISM 01.2 in the following sections: • Exhibit C, Inorganic Target Analyte List (TAL) • Exhibit D, Analytical Methods • Exhibit E, QA/QC Requirements CLP ISM 01.2 & ILM 05.3 Standards for ICP For ILM 05.3, a standard must be run at the Contract Required Detection Limits (CRDL). To verify linearity near the CRQL, this standard is analyzed at the beginning of the analysis run, after the ICV/ICB and before the ICSA and ICSAB. In addition, this standard must be run at a frequency of not less than 20 analytical samples and at the end of the analysis run, followed by the ICSA/ISCAB. The sequence order is CCV, CCB, CRI, ICSA, ICSAB, CCV, and CCB. For ISM 01.2, at least one of your calibration standards must be at the Contract Required Detection Limit (CRDL). This standard, when diluted, can be used as a calibration standard to fulfill this requirement.
Intended Use
Multi-element standards for ICP instrumentation
More Information
Accredited by A2LA to ISO/IEC 17025/2017 and ISO 17034:2016|Certified to DQS to ISO 9001:2015|CLP ISM 01.2 & ILM 05.3 Standards for ICP
Documents
Product Information
- BrandSpex
- Volume125 mL
- Unit of MeasureEA
- Storage Condition15 to 30°C
- Product TypeInorganic Standard
- Raw MaterialFive 9s & Purification as available
- CertificationSingle: Direct ICP Analysis
Notifications
Component Table
Calcium | 5,000 µg/mL | 10% HNO3 | |
Magnesium | 5,000 µg/mL | 10% HNO3 | |
Potassium | 5,000 µg/mL | 10% HNO3 | |
Sodium | 5,000 µg/mL | 10% HNO3 | |
Aluminum | 200 µg/mL | 10% HNO3 | |
Barium | 200 µg/mL | 10% HNO3 |