ICP-MS Analytes B4 (125 mL)

SKU: CL-INT-B4

Description

CLP Standards for ICP & ICP-MS Our Contract Laboratory Program (CLP) standards allow you to Calibrate with Confidence®. The standards are to be used in conjunction with the Statement of Work for Inorganic Analysis; Multi-Media/Multi-Concentration Document Number ILM 05.3/ISM 01.2. The final ICP check, performed in our own laboratories, is your stamp of assurance. We calibrate our instruments with traceable reference materials and show you the actual found value of the solution you receive, not just an ideal, calculated number as so many other standards manufacturers do. The combination of elements, concentrations and matrices listed have been diagnosed by SPEX CertiPrep for convenience of use and stability. US EPA SOW ILM 05.3/ISM 01.2 gives specific procedures for the methods of analysis, target elements, and concentrationlevels. Standards are specified not only by the elements present and their relative concentrations, but also the order and frequency of running standards, blanks and samples. Details of these specifications may be found in the US EPA SOW ILM 05.3/ISM 01.2 in the following sections: • Exhibit C, Inorganic Target Analyte List (TAL) • Exhibit D, Analytical Methods • Exhibit E, QA/QC Requirements CLP ISM 01.2 and ILM 05.2 & 05.3 Standards for ICP-MS For verification of inter-element and background correction factors at the beginning and the end of each analysis run. In addition, a verification must be done after every 20th sample. Two solutions are required for the most common interference check: Solution A, the interferents alone (CL-INT-A2) and Solution AB, a combination of interferents (CL-INT-A2) and analytes (CL-INT-B3 or CL-INT-B4). Solution A is prepared by diluting CL-INT-A2 10-fold. Solution AB is prepared by diluting CL-INT-A2 10-fold and CL-INT-B3 or CL- INT-B4 100-fold; for example (10 mL) of CL-INT-A2 and 1 mL of CL-INT-B3 or CL-INT-B4 into a 100 mL volumetric flask, brought to volume with a matrix blank. Once prepared, the solutions should be analyzed consecutively, starting with Solution A.

Intended Use

Multi-element standards for ICP-MS instrumentation

More Information

Accredited by A2LA to ISO/IEC 17025/2017 and ISO 17034:2016|Certified to DQS to ISO 9001:2015|CLP ISM 01.2 and ILM 05.2 & 05.3 Standards for ICP-MS

Product Information

  • BrandSpex
  • Volume125 mL
  • Unit of MeasureEA
  • Storage Condition15 to 30°C
  • Product TypeInorganic Standard
  • Measured Impurities68 elements to ppb (product)
  • Raw MaterialFive 9s & Purification as available
  • CertificationDual: Wet Chem, ICP Direct & ICPMS Impurities

Classification/Permits

  • CCL

    International Customers only. This product is controlled through the U.S. Department of Commerce, Bureau of Industry and Security (BIS); a license authorizing export from the U.S. is required prior to shipment

Notifications

  • warning
    Shipping This product is not available for shipping outside of the US.

Component Table

Chromium 40 µg/mL 5% HNO3/tr. HF
Manganese 30 µg/mL 5% HNO3/tr. HF
Zinc 30 µg/mL 5% HNO3/tr. HF
Copper 25 µg/mL 5% HNO3/tr. HF
Lead 25 µg/mL 5% HNO3/tr. HF
Nickel 25 µg/mL 5% HNO3/tr. HF
Antimony 20 µg/mL 5% HNO3/tr. HF
Arsenic 20 µg/mL 5% HNO3/tr. HF
Barium 20 µg/mL 5% HNO3/tr. HF
Beryllium 20 µg/mL 5% HNO3/tr. HF
Cadmium 20 µg/mL 5% HNO3/tr. HF
Cobalt 20 µg/mL 5% HNO3/tr. HF
Selenium 20 µg/mL 5% HNO3/tr. HF
Silver 20 µg/mL 5% HNO3/tr. HF
Thallium 20 µg/mL 5% HNO3/tr. HF
Vanadium 20 µg/mL 5% HNO3/tr. HF